Surface Mounted Multiple-Point
Panic Exit Deadbolt Lock
SECTION 08700 DOOR HARDWARE
Part 2 - Products
2.01 - Materials and
Manufacturers
Locksets and Latches
1. Lockset shall be heavy
duty type in function, trim and finish as specified.
2. Emergency Exit
Lock
a. Emergency exit security
deadlock shall be Securitech Model #4945, a surface mounted
four-point deadbolt system with an emergency exit paddle
on the interior which instantly retracts all moving deadbolts
with one depression of the paddle. One 360º key revolution
from the exterior side, where listed on the hardware schedule,
shall project or retract all the moving deadbolts. The lockset
shall be capable of installation on a door 3x7
or less.
b. Moving deadbolts shall
project a minimum of one full inch in each direction. The
upper deadbolt shall be hardened steel and shall be a minimum
five inches long. The lock side and vertical bolts shall
be moving. A fixed bolt shall be affixed to the edge of
the door for a fourth locking point.
c. The lock shall be
located at the lock edge of the door, installed at a height
of approx. 42-1/2 inches. The vertical deadbolts shall travel
within aluminum channels which are affixed to the door by
steel locking brackets which are affixed to the door with
four self-drilling bolts per bracket.
Exterior operation and
guard plate shall be as designated in the hardware schedule.
Alarm function shall be as designated in the hardware schedule.
All alarms are to contain an anti-tamper switch which will
sound the alarm if the special alarm cover screw is removed
without shunting or turning off the alarm.
All cylinders are to be supplied by others. See separate
keying information.
Specific model information:
Locking Points:
49__ = Securitech
MP Panic Exit Police Lock Series
45 = 4 locking
points
35P= 3 locking
points on each leaf of a pair of doors
31= 3 locking points
(top & bottom moving, fixed hinge bolt)
32= 3 locking points
(horizontal & top moving, fixed hinge bolt)
33= 3 locking points
(horizontal & bottom moving, fixed hinge bolt)
34= 3 locking points
(horizontal, top & bottom moving)
21 = 2 locking
points (top & bottom moving)
22= 2 locking points
(horizontal & top moving)
23= 2 locking points
(horizontal & bottom moving)
Alarm Options
-AL1 = Momentary key
switch (alarm always active; key shunts momentarily, two
keys and cylinder provided)
-AL2 = On/off key
switch (alarm can be left in disarmed condition, two keys
and cylinder provided)
-AL3 = Momentary
by mortise cylinder (alarm always active; key shunts momentarily,
mortise cylinder by others)
-AL4 = On/off by
mortise cylinder (alarm can be left in disarmed condition,
mortise cylinder by others)
-BA=Alarm to contain
low battery alert to provide audible signal approx. every
thirty seconds when battery voltage is below seven volts.
-CT=Digital counter
records a sequential number each time the deadbolts are
retracted
-DP=A separate
power supply shall be provided which accepts 110v incoming
power and provides a 9v output for the alarm unit. One power
supply shall be sufficient for a single or pair of doors.
-LE=An LED shall
be mounted on the alarm cover to provide a visual signal
when the alarm is armed.
-EK=Exterior key
operation for the "AL4" or "AL2" alarm
shall be provided. Cylinder by others.
-ED=Alarm type
"AL4" or "AL3" to have an optional exit
delay. Exit delay will mean that the alarm will not sound
if exit is made through the door within ten seconds after
the alarm is turned off and then on prior to the exiting.
Exterior Operation Options
None:
-XX = No exterior operation
Keyed Entry with:
-PH = Hardened
steel guard plate with pull handle for rim cylinders
-PB = Hardened
steel guard plate with pull handle and preparation for Best
removable core cylinders
-SG = Stainless
steel guard plate with Securiguard magnetic cylinder protector
-RG = Stainless
steel guard plate with Securiguard cylinder protector prepped
for "Best" cylinder
Additional Options
-49SB=Supply a special
angled strike for installation on the inactive leaf of a
pair of doors when an exit lock with a horizontal bolt is
to be installed on the active leaf.
-49TB=Steel thru-bolt
mounting plates with two bolts which mate with interior
mounting bracket. Interior bracket will be fastened by two
additional self drilling screws.
-49PE=Paddle extension
for areas where local codes require a larger surface.
-OSD=Please supply
door size information if over 3x7.
|