| Lockset shall
be MAGLATCH, model # 9030 (or #9032: Heavy Duty Model), as
manufactured by Securitech Group, Inc., or approved equal.
Lockset shall
be a heavy-duty mortise lockset which contains a 3/4"
deadlatch. Interior exiting shall be by depression of a
lever handle. Exterior unlocking shall be either by a key
and depression of the lever handle or through an interface
with the intercom or card access system, which shall send
an impulse to momentarily release the lever handle, allowing
it to be depressed and retract the latch. The exterior shall
always be in a "Fail Secure" mode: key is always
required for entry. Security is maintained in the event
of a power failure.
Exiting shall be possible
at all times with a single motion or action and is "Fail
Safe". Power is not required for exiting.
An electromagnetic lock,
containing 1,200 lb. of holding force shall be installed.
The electromagnetic lock shall be de powered simultaneously
with the movement of either lever handle retracting the
latch. All switches for the electromagnetic lock shall be
contained within the trim units. There is to be no special
movement or action required to release the magnet.
The exterior lever handle
shall be fabricated of cast stainless steel and contain
a slip-clutch apparatus which will lower or rise without
retracting the latch if depressed without insertion of the
key or electric release. The exterior lever handle unit
shall also contain the ability to replace the cylinder without
removing the interior or exterior trim plates. Access to
remove the cylinder shall be via allen screw through the
interior trim. A series of two allen screws, one of which
is to be removed, shall be used. The cylinder shall be protected
within a hardened steel cylinder protector.
The interior lever shall
also be made of cast stainless steel and shall contain a
removable cap at the hub, which when removed via allen key
shall allow for the removal of the spindle. After removal
of the spindle the lockset is to be able to be removed without
any further removal of the lock trim. The bolt sections
of the interior trim are to be covered by Trim Brackets
which are pop-riveted to the door.
Lockset trim shall be
thru-bolted with four bolts and one-way threaded caps. Power
required for the exterior trim is 24vAC, 30va (or 24vDC
if so specified). A Handle Stop is to be affixed to the
bottom of the exterior lever handle unit and shall protrude
outward so as to prevent handle rotation over 180 degrees.
For 9032 Model Only:
Exterior Trim Brackets shall be affixed over the exterior
lever handle unit at the cylinder and lever handle and affixed
to the door with security fasteners. All exposed screws
are to be tamper-proof.
The electromagnetic lock
is to be affixed to the header of the frame. A separate
aluminum channel is to be installed which envelopes the
electromagnet and protects it against vandalism. The channel
is to be affixed to the header with security fasteners.
The channel shall be constructed of one aluminum piece with
1/8" thick walls.
ADD FOR Outswinging
Doors
A Latch Protector shall be mounted to protrude over the
edge of the door and cover the latch and strike on all outswinging
doors. |