Access Control Interface Control Trim
 

LXK Series Electrically Released Trim For Kawneer® Doors

 

#LXK-100-1A
(pair of doors, 1 active leaf)

Elements

Internal Vertical Rod Device With Rectangular Push Plate:
- Existing to remain
- Retrofit switch supplied for activation on panic bar depression to send signal
- Retrofit switch provided for 2nd door

Exterior Trim:
- LR style standard (GG & UG) also available
- Mortise cylinder (by others)
- DC release from access control system standard - Add "-RE" for re-entry (fail-safe entry)
- Special activating cam for use with Kawneer internal exit device
- Custom mounting plate to bypass vertical rods withing door

Power Transfer:
- Yamaka (YMK20) 3 Provide

Dummy trim may be ordered separately for in-active leaf (matches trim style).
LR


Standard Trim Style

 

Alternative Trims
 
GG
 
UG
 
FAIL-SAFE (re-entry) function available; Designate "-RE"
How Does It Work?
Designed for retrofit installation to existing Kawneer exit doors, LXK control trim and switches allow integration into the access control system.

When exiting, the panic bar activates an internal switch which sends a signal to the access control system to generate a local alarm. Exiting without sounding an alarm may be accomplished via use of a card reader and valid card.

To enter, the access control system can momentarily energize the lever or the key may be used to release the lever. An optional key usage switch can send a signal to the access control system to let it know that a key has been used in place of the access control system.

Kawneer® is a registered trademark of Kawneer Company, Inc.

Includes Retrofit Pushbar Signal Switch

LXK-100-1A
Interior:
Existing integral push plate activated switch for both doors.

Retrofit Kit:
Includes push plate activated switch for both doors

Exterior: Retrofit key & electric release trim (24vDC)
Power Transfer:
3 individual Yamakas
Wiring Info:

Active Leaf (with exterior trim):

A) 2 wires from exit device to alarm system for Push Plate depressed signal (R-T-E or alarm initiation)
B) 2 wires from exterior trim to power supply for release

In-Active Leaf (no exterior trim):
A)2 wires from exit device to alarm system for Push Plate depressed signal (R-T-E or alarm initiation)

This model features three individual Yamaka Power Transfers to be mounted at the header for power and signal transfers.
Illustration Shows "Dummy Trim" On Inactive Leaf
Interior
Exterior

 

 

 
Wires
Interior
Existing Panic Bar
A
Latch
Internal Vertical Rod
A
Pushbar Activated Signal
Yes
2 + 2
Latch Position Switch
No
A
Exterior
Keyed Lever Trim
A
Electric Release
24vDC
2
Key Usage Switch
No
A
Power Transfer
Yamaka, At Top
A
DOOR & FRAME PREPARATION:
Existing integral pushbar exit device is retained.

HANDING: LHR or RHR

CYLINDER: Mortise cylinder required (by others).

CYLINDER PROTECTOR (UG trim):
Standard, removable core or special (contact factory).

POWER SUPPLY:
From access control system