Exit Device Ordering Information
Models Numbers Creator
Panic Bar
Exterior Trim & Specials
Swing
Series,
Exit
Type
Device
Width
Fire-Rated
Interior Switch Choices
Wiring Method
931
941
932
942
944
935
936
A
B
C
F
2
3
5
0
I
L
T
Trim Style
Key &
Trim Function
Electric Or Mechanical Release
Exterior Switch Choice
Maglock &
Specials
U
G
X
S
C
P
D
K

X
A
D
R
M
2
3
5
0
E
B
Q
Y
-

Z
Swing
L
R

(L=LHR)
(R=RHR)
Standard Finish Information
Panic
Bar
Ext Trim
Style
Ext.
Trim



630
UG
676
630
GG
630
630
LR
676
630
XX
none
Other panic bar and trim finishes are available: please contact the factory
Electric release does not require special high in-rush power supply
Sample Model Number:
934AF5T-GSD2E-L
Breakdown:
Panic Bar
Rim Device
36" door
Fire-rated
R-T-E switch
Mag switch
Transfer cable
Trim & Specials
GG-style
Single entry
DC release
Mag switch
Electromagnet
Swing
LHR
See Electrolatch or Maglatch catalog cuts for full electrical and cutoff switch information
Device Widths
Trim Styles
Key & Trim Functions
Designation
Opening Width
-A-
30" - 36"
-B-
36-1/2' - 48"
-C-
24" - 30"
Switch Choices
0
No switches
2
N.C. Switch (mag release)
3
N.O or N.C. (Request-To-Exit)
5
2 switches - one type "2" and one type "3" switch
Wiring Methods
All models feature cross-over connector from exterior trim to panic bar. Incoming wires are connected at the hinge edge of the door.

 

 

 

 

I
Internal: Panic Bar & Exterior Trim wires exit at rear of panic bar into door.
L
Long lead wires (5') on internal method
Power transfer required for "I" & "L"
T
Transfer Cable:
vandal-resistant
armored cable from rear of
panic bar with all wires
 
U
UG
 
- Heavy-Duty
- Slip-Clutch vandal----resistant lever
- Optional electric
- release & magnetic
- lock control
 
G
GG
 
- Narrow-style, aesthetic design
- UG features and options
 
X
XX
 
- No exterior trim

 

 

 

 


See "Trim Styles" catalog in electric locking section for full trim features, details sizes and options
 

Contact Factory With Special Function Or Feature Requests
S
Standard (Single Entry By Key)
C
Classroom
P
Passage
D
Dummy
K
Key Useage Switch
(Single Entry Function)
X
Access Control Cut-Off Switch
(Single Entry Function)
Electric Release Options
A
AC (24vAC, 30va)
D
DC (24vDC, Low 1/4 amp draw)
R
Re-Entry (Fail-Safe exterior lever) DC solenoid (info as above)
M
Mechanical only (no electric)

 

 

 

 

 

Electromagnetic Lock

E
Electromagnetic Lock funished (invisalock # IL1002)
B
With bond sensor
Q
With door status switch
Y
With bond sensor and status switch
Latch Position Switch
Z
Provides signal on latch status
 
Strike Info For Vertical Rods
(included with model)
Top:-------------------#STR931T
Floor:-----------------#STR931F

Special Order
Floor Strike
With Edge Plate---#STR931P
Strike Info For Rim Devices
(included with model)
Standard:-------------#STR934
Fire-Rated:-----------#STR934F

Special Order
Double Door