The links on this page are PDF files of all the systems Securitech sells.
SYSTEM TEMPLATES

Acrobat Reader 4.0 or Later is Required Click Here To Download 

Last Updated 6/28/04

NOTE: PLEASE DO NOT USE ANY OF THE PRINTED TEMPLATES AS A DOOR MARKING TEMPLATE. THE TEMPLATES ARE NOT TO SCALE. USE THE DIMENSIONS ON THE TEMPLATE AS YOUR GUIDE TO PREPARE THE DOOR.

4800 SERIES -- MP Police Lock
4800 Series MP Police Locks are surface-applied. The door does not need special reinforcement. Securitech does not recommend factory preparation of holes in most cases. All holes are to be prepared in the field. If you need the template for any reason you can print it out from here. Securitech does not recommend pre-drilling of the doors.

4800-XX | 4800-H | 4800-BG | 4820V-EIL | 4840-TA2-FT | 4840-TA6-FT | 4840-RT | 4840-SG
4840-TG
| 4840-TG-PC

4900 SERIES -- MP Panic Exit Lock
All 4900 locks are to be prepared in the field. There are some special templates that can be printed, but Securitech does not recommend preparing the door or frame in advance.
Grout Box Info Can Be Dowloaded HERE

4945-SL Exterior Trim RHR | 4945-SL Exterior Trim LHR
4900 Thru-Bolt Bracket | 4935P Thru-Bolt Bracket | 4935FSP | 49FSP  
4945ML-PH
 | 4945ML-PB | 4945ML-BF | 4945ML-SG | 4945ML-RG

__________________________________________________________________________

5000 SERIES -- Multi-Bolt

________________________________________________________

6000 SERIES -- Securiguard™ 
6101 | 63PT1
________________________________________________________________

COMMON WINDSTORM HARDWARE TEMPLATES BY VARIOUS DOOR MANUFACTURERS and type of Windstorm

LOADING OF FILES BELOW MIGHT TAKE A BIT OF TIME DEPENDING ON THE SPEED OF YOUR CONNECTION


FEMA 320/361-TORNADO DOOR HARDWARE TEMPLATES

CECO 8000-FEMA Door Prep Templates Click here for booklet

CURRIES 8000-FEMA Door Prep Templates Click here for booklet

STEELCRAFT 5000/8000 FEMA Door Prep Templates Click here for booklet

MESKER 8000 - FEMA Door Prep Templates Click here for booklet

AMBICO 8000 FEMA Door Prep Templates Click here for booklet

HURRICANE (Florida) DOOR HARDWARE TEMPLATES

FIREDOOR Corporation-NOA Approved Door Hardware for large missile applications.
Click here for template booklet
____________________________________________________________________

8000 SERIES -- Centurion™ - Auto-Bolt™ - P*E*D*S
___________________________________________________________________

9000 SERIES
Maglatch™, Electrolatch™, Guardian™, Invisalock™

MORTISE LOCK PREP & STRIKE PREP TEMPLATES
Securitech control trim can be used with mortise locks of all manufacturers. The critical relationship between the Securitech trim and the mortise lock is the hub location. All trim  | measurements are related to this location.

BEFORE PREPARING THE DOOR AND FRAME:
Confirm which series mortise lock is to be used!

A) Select The Mortise Lock to Be Used:

  1. STANDARD SECURITECH MORTISE LOCK ("A" SERIES)
    Use the 9000SFA template with all 90XX (9010, 9012, 9020, 9022, 9030, 9032, 9034) locks that are to be installed on a wide stile door. This template will allow you to prepare for the strike and mortise cutout. Backset is 2-3/4"
  2. SPECIAL MINI MORTISE LOCK FOR MEDIUM STILE DOORS OR GATES
    Use the 9000SFM template with all 90XX (9010-MML, 9012-MML, 9020-MML, 9022-MML, 9030-MML, 9032-MML, 9034-MML) series locks that are to be installed on a medium stile door or gate. Minimum rail size is 3"
  3. SPECIAL NARROW STILE LOCK FOR NARROW STILE ALUMINUM DOORS OR GATES (2" RAIL)
    Use the 9000SF-NLS template with all 90XX (9010-GG, 9012-GG, 9020-GG, 9022-GG, 9030-GG, 9032-GG, 9034-GG) series locks that are to be installed on a narrow stile door. Backset is 1-3/8"
  4. SPECIAL "SARGENT" MORTISE LOCKS:
    Use the 9000SFS template with all 90XX (9010, 9012, 9020, 9022, 9030, 9032, 9034) locks that are to be installed on a wide stile door. This template will allow you to prepare for the strike and mortise cutout. Backset is 2-3/4"

B) Select The Model # & Trim To Be Used

  1. Trim Templates For "UG" Style Trim:

2. Trim Templates For "GG" Style Trim:

9010 Electrolatch™ | 9012 Electrolatch™ | 9020 Maglatch™
9022 Maglatch™
| 9030 Maglatch™ | 9032 Maglatch™

C) Select The Electromagnet To Be Prepared (If Appropriate - check model)

  1. Electromagnetic Lock Template:
    Use INS MAG frame preparation information if you are preparing a frame for our EML-1002 Magnet.

Contact the factory for 93XX Series (Exit Device) templates.

Power Transfers
Electrified Mini-Hinges, Ball Bearing Hinges & 
Modular Power Transfers

ECH-FM | ECH-FM-8 | EH-4.5 | EH-4.0
YMK-20 | YMK-21


Website material and images are Copyright © 2004 By Securitech Group. All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.
Website Optimization and Design By Cornerstone Website Services
.