START-OF-DAY
ENTRY
Key is inserted and rotated in exterior keyswitch, then removed.
Activates timer for 5 second electromagnetic lock release
(time is field adjustable).
Key is inserted and rotated in panic bar cylinder. Retracts
latch and allows door to be opened (while electromagnet is
released by timer).
Pull door open and remove key.
Door relocks behind person entering and remains in locked
mode until another action is taken. |
DAYTIME
REMOTE RELEASE MODE
Key is inserted and rotated in interior keyswitch, then removed.
Activates electric bolt retraction; panic bar remains in normal
position, but bolts are retracted. Door is secured by electromagnet
only.
To allow entry: Person in office responds to intercom and
presses door release button. Electromagnets are released momentarily
as button is depressed.
To cancel mode & return to locked condition: Insert key
& rotate in interior keyswitch.
|
OPEN
FACILITY MODE (ENTRY
WITHOUT REMOTE - PUSH/PULL)
Key is inserted and rotated in keyed dogging cylinder on panic
bar, then removed. Panic bar is held down. Latches are retracted
and electromagnets released.
Repeat for each door to be converted to push/pull operation.
To cancel mode & relock door: Insert key and rotate to
release panic bar. Latches and electromagnet lock door. |