| Security
Hardware for System Integrators |
|
|
The following system has
been designed for use by The Home Depot and meets their specific
gate locking needs. Similar systems ar available for use on
doors. Contact Securitech for additional information.
Elements By Individual
Gate
|
Elements F |
|
Delayed
egress electromagnetic lock & armature in
weatherproof enclosure (requires conduit for wiring
from TSE-HD37) |
Elements G
|
See
separate catalog cut for details on exit
lock
|
|
|
Multi-point
exit lock & local alarm modified for delayed
egress system (includes armored cable for wiring
to TSE-HD37)
(includes delayed egress sign for gate)
Requires mortise cylinder with straight Yale cam
(by others) |
|
Elements H |
|
Terminal
strip enclosure
Weather-proof
(requires conduit for wiring from controller) |
|
Order
one of each of the above model numbers for each gate.
Elements For System
|
Elements
D & E |
|
Multi-point
alarm & status panel for exit locks
Modified for delayed egress system |
| |
|
|
|
Elements
A, B & C |
|
Delayed
egress controller & power supply
Includes power supply
Accommodates up to 3 doors |
|
|
Terminal
strip in junction box at each gate:
2 power wires from magnet
2 body status wires from magnet
2 wires from exterior key switch (momentary) to
interrupt magnet power (for entry)
4 wires from key switch box to DPM module
3 wires from DPM module to DPS5
2 wires from interior key switch to turn magnet
on/off (same switch as alarm on/off) |
|
Order one of each of
the above model numbers for the store.
Power
Information
110vAC is required by the Delayed Egress Controller/Power
Supply. All power for the electromagnetic locks and
alarms are supplied by this power supply. Low voltage
wire is run to each gate.
Fire Alarm Integration
The Controller includes fire alarm connection, as required
by code.
|
Conduit
Information
14 conductor (18 gauge) wire is to be run from the controller
to each individual gate. |
|
|