Electrolatch Sample Wiring Scenarios
Standard Electrolatch

Goal: Door to be electrically released from access control system or remote pushbutton

Elements:
--Lockset
----Standard security:
----9010-GG-DC

----High risk of
------ vandalism
----9010-UG-DC
--Power Supply:
--PS-91

1
Power Supply
2
Power Transfer Device
3
Electrically Released Lever Trim
4
Access Control Reader/Controller
PS 91

If access control system can output 24vDC, Securittech power supply is not required.
Electrolatch Re-Entry

Goal: Door to be Fail-Safe on stairwell side to meet high-rise "Re-Entry" codes and to be electrically released from access control system or remote pushbutton

Elements:
--Lockset
--9010-GG-RE

--Power Supply:
--PS-91-RE
1
Power Supply
2
Power Transfer Device
3
Electrically Released Lever Trim
4
Access Control Reader/Controller
PS 91-RE
The Fire Alarm Panel circuit will immediately cut-power to meet lifesafety and Re-Entry code requirements.

 

 

 

 

 

 

 

 

Electrolatch Signal Lock

Goal: Door to be electrically released from access control system or remote pushbutton and provide Request-To-Exit signal to access control system

Elements:
--Lockset
--SME-D1-GS

--Power Supply:
--By access control system

Most access control systems can output 24vDC. Therefore, a Securitech power supply is not required in Electrolatch "DC" applications and Electrolatch Signal Lock applications.
1
Access Control Power Supply
2
Power Transfer Device
3
Interior Trim with Switch
Exterior Trim with Electric Release
4
Access Control Reader
Power Supplied By Access Control System

Full elevations and point-to-point wiring diagrams are available for all Securitech Control Trim, Signal Lock, Entry & Exit Control Systems and single door power supplies. Contact the factory with your requirements.