Load Bearing Switches
|
|
|
Both
the interior and exterior levers of the UG or GG series may
contain independent switches, rated at 5 Amps, 30vDC. These
can interrupt the electromagnetic lock's power and have a
mechanical life of 10 million cycles. Depressing the lever
opens the circuit. |
|
|
Electric
Release Options
|
|
|
24vAC,
30va transformer required |
|
|
24vDC transformer
required |
|
|
24vDC,
Fail-Safe Re-Entry Function |
|
|
|
|
|
The exterior
cylinder is used to unlock the lever for extended
periods. A key is not required for entry until
the lever is re-locked by key. On models with
electric release,
the electric release will function while the lever
is locked. |
|
Applications:
- Classrooms
- Office Entry
- Public Spaces where latching is required to
meet fire code, but free entry is desired at certain
times |
|
|
|
|
|
|
| UG
& GG interior trims may include an optional signal
switch for use with alarmed or access control doors.
Depressing the interior lever actuates the switch. |
|
|
|
|
The
interior lever of the LR trim is locked in the downward
position, which keeps the latch retracted. The door
can then be pushed or pulled open. The lever is released
and the door re-locked by use of key. Exiting is possible
at all times, regardless of mode. |
|
Applications:
- High-Traffic Storefront Entry
- Public Arena
- Parks
- Museum
- Education Institutions |
|
|
|
Cylinder
Protector
(UG Trim Only)
|
|
|
Full face
steel cylinder protector is standard for regular cylinders. |
|
|
|
"BEST"-type
IC core cylinders require a "8" plug opening. |
|
|
|
Yale
IC core cylinders require an oval keyhole opening. |
|
|
|
Access
Control Cut-Off Switch
|
|
|
Access control systems
can be complicated to program and turn on and off. Frequently
a computer is needed to change status, time zones, etc.
The cut-off switch feature allows a clockwise rotation
of the key to toggle the access control system on or
off. The supervisor does not need to have any programming
skills to turn the system off for a defined period (after
hours, weekend, etc.) or turn it back on. |
|
|
|
Key
Usage Switch
|
|
|
| UG & GG exterior
trims may be unlocked by key or electrically. To identify
use of a key instead of the access control system, the
KU switch activated when the door is unlocked by use
of a key, instead of the access control system. |
|
|
|
UG
Cover-Up Underplate
|
|
|
|
|
Designed to cover
multiple holes on the door from old hardware and give
the door a clean lock after the installation. Will
cover
|
Folger-Adams
"Levertrak" holes.
Ordered as a separate item. Non-handed. |
|
|
|
Long
Lead Wires
|
|
|
| Eliminate
wiring connections in the lock area of the door. Long
8' lead wires allow easy connections off the door. Also,
the system may be tested for safety without removing
the lockset. |
|
|
| Cylinder
Information |
|
|
Standard 1 1/8"-
1 ¼" mortise cylinders are recommended.
Specify if longer cylinders are to be used for special
collars or cylinder protectors.
Cloverleaf cam is
used for single-entry function. Short Adams-Rite type
cam is required for classroom function.
|
|
Cloverleaf
Cam
|
|
|
|
Optional
Lever Designs
|
|
|
|
|
|
 |
|
Special lever
designs are available on special order for use with "GG"
trim to match other manufacturer's trim used on a project. |
|
|